Contents


Global COE
Program pamphlet Tokyo University of Science Forum on fire safety in Asia

Fire Research and Test Laboratory

In March 2005, TUS opened the Fire Research and Test Laboratory, Center for Fire Science and Technology (hereinafter, CFSaT) as a research facility specializing in fire science that is equipped with world-class laboratories and equipment. CFSaT is located on the Noda campus. The CFSaT building area is approximately 1500 m2 with a total floor area of 1900 m2 and a ceiling height of 20 m. The members of CFSaT designed this research facility with its cutting-edge equipment based on their experiences, enabling world-leading research to be conducted here as a center of fire science.

CFSaT is comprised of two major buildings, the Full-Scale Fire Test Hall and the Small Test Laboratories, according to their functionality. The Full-Scale Fire Test Hall is a large-scale laboratory with a floor area of 1000 m2 and a ceiling height of approximately 18 m. This building is adjustable to full-scale experiments that vary depending on such parameters as fire control or fire-proof performance of structural members and materials, burning behavior of combustible materials, and smoke movement. In order to provide practical education and research at the Center, as shown below, this building is equipped with devices and gauges that are capable of creating actual situations based on theory.

The Full-Scale Fire Test Hall is also equipped with essential tools for fire research such as smoke-collecting hoods and fire-proof furnaces. Utilizing the large-scale space, the building can be used for structural fireproof tests loaded with actual-scale structural members and frames, fire behavior tests of office spaces loaded with combustible furniture fittings and equipment, smoke behavior tests of an atrium space, and burning behavior tests of vehicles. The Small Test Laboratories are comprised of a multi-purpose experiment room, a cone calorimeter room, temperature and humidity controlled rooms, a library, an observation room, a data processing room, conference room, a precision measuring equipment room and a storage room.

icon_pagetopTO THE TOP OF THIS PAGE

Cone Calorimeter Testing Device (ISO 5660)

This device is used to examine ignitability and the exothermal properties of construction materials using thermal radiation. A test object is placed under the conical-shape electric heater which controls the thermal radiation to the object, and a pilot flame is applied to the object 10mm from its surface. The ignition time and the heat release rate can be measured per thermal radiation that can be set in the range of 0 to 50 kW/m2.

PIV Combustion Field Measurement System

This system measures the instantaneous velocity and/or microscopic flow rate of, for example, the combustion field and the smoke plume motion. With this system, in the case of using a tracer (microscopic particles) and light source such as strobe light and laser, a picture of the reflection can be taken by an ultrafast camera to instantaneously obtain two-dimensional data of the flow rate on the target field.

Secondary Combustion Furnace

The smoke ventilation (collection) fan at the hood vacuums up the combustible gas containing black smoke that is induced from a burning source, and this furnace re-heats the smoke to 800 to burn completely and then eliminates the smoke. There are 4 heating burners which can produce 4.8 Mkcal/h in total.

Structural Fire Testing Furnace (Medium scale)

This unit is used to evaluate the fireproof performance of various structural members such as columns, beams, floors and walls. The unit can control the heat to the standard heating temperature and furnace pressure set by ISO 834. The heating furnace, with dimensions of 1.5 m (W) x 1.5 m (D) x 1.5 m (H), can also provide immediate heating.

Structural Fire Testing Furnace (Large scale, for Walls)

This unit is used to evaluate the fireproof performance of an exterior wall under fire and can control the heat to the standard heating temperature and furnace pressure set by ISO 834. There are 20 burners on the lateral side, and this can heat up to a 3.5 m x 3.5 m area. The unit is also suitable for performing heat tests.

Calorimetry Hoods (5 m × 5 m)

This unit is used to analyze the burning characteristics of furniture and equipment in a room by burning them and collecting the burning gas. The duct is equipped with devices for flow measurement and sampling. The design heat release rate is 2 MW at maximum, and the smoke suction power is 600 m3/min at maximum. A movable unit (4 m x 4 m) is also available.

Full-Scale Compartment for Fire Experiment (with Water Pump)

This fire compartment is 6 m (W) x 6 m (D) x 2.7 m (H) in actual size, and the sprinkler system can be attached to the ceiling. The compartment is mainly used to evaluate the fire extinguishing performance of sprinkler systems and also has used for experiments on smoke movement during sprinkler system activation.

Room Corner Testing Unit (ISO 9705)

This unit is comprised of a space of 2.4 m (W) x 3.6 m (D) x 2.4 m (H) (approximately, the size of a 6-tatami-mat room) and an opening 0.8 m (W) x 2 m (H). It can be used to recreate a fire in a room with furniture and dry walls, which can be developed into a fully developed fire. In addition, flashover experiments can be performed with this unit by recreating fires that spread to entire rooms in a short time period, and then combustible gas concentration and temperature distribution data can be collected. The development of the fire can be captured by video camera.

ICAL Testing Unit (Heat Radiation Panel)

This unit is designed to elucidate the burning behavior of combustible materials under the condition where a certain heat flux was given through radiative heat transfer. The unit can also be used to investigate the behavior of members exposed to radiative heat. The panel heater has a heating area of 1.75 m (W) x 1.38 m (H). Members can be exposed experimentally to surface temperatures up to 950 and a heat flux of 50 kW/m2.

icon_pagetopTO THE TOP OF THIS PAGE

Total of visitors 2,331 people

Date Visitor Number of people
2013.10.29 Demonstration_combustion experiment_sheets of bus 10
2013.8.8 Open Campus 31
2013.4.17 Tongji Uiversity, China 21
2012.11.14 Demonstration_Tokyo Fire Department 20
2012.8.7 Open campus 86
2012.7.6 Ministry of Education, Culture, Sports, Science and Technology 2
2012.7.1 Optional Laboratory Tour on work shop between USA and Japan 21
2011.10.7 Tokyo Fire Department / Japan Food service Equipment Association 7
2011.9.12 The University of Kitakyushu / Oita National College of Technology 5
2011.8.8 Open campus 67
2011.7.6-7 The Japanese Electric Wire & Cable Maker’s Association, demonstration, observation 7
2011.6.9 Faculty of Industrial Science and Technology, Department of Materials Science and Technology, TUS 3
2011.2.2 Joint Usage/Research Center, Demonstration (Verification experiments for the THz electromagnetic wave) 25
2010.11.26 Symposium of information exchange between academic, industry and government 36
2010.11.9 Flame Retardant Chemicals Association of Japan 16
2010.11.5 The University of Kitakyushu 5
2010.8.7 Open campus 40
2010.7.23 Ibaraki Prefectural Takezono High School 3
2010.4.11 Scout Association of Japan, Scout Chiba 150
2010.3.8 Fire ceremony of Structural Fire Resistance Furnace (Large scale, for Columns, Beams, Floors etc.) 43
2010.3.5 Japan Nuclear Technology Institute 12
2009.12.24 Kangwon National University 5
2009.10.31 Faculty of Pharmaceutical Sciences, TUS 10
2009.10.29 Home educational class in southern aria of Noda 80
2009.10.27 Material Life Society, Japan 16
2009.10.8 Japan Bousaisi Organization 5
2009.9.11 Architectural Institute of Japan 10
2009.8.28 professor of Chiba Institute of Science / professor of City University of Hong Kong 2
2009.8.21 Fire Department of Osaka City / Workshop of students studying abroad 15
2009.8.8-9 Open campus 80
2009.7.25 Lifelong study, science class for parents and children 90
2009.2.12 Swiss Federal Institute of Technology / Tokyo Institute of Technology 5
2008.11.2 Koyokai in Tokai aria, TUS 40
2008.8.8-9 Open campus 80
2008.7.25 Parents, Saitama prefectural Kasukabe High School 80
2008.3.13 Xi’an Technological University in China 20
2008.3.12 Inviting speakers of international symposium 10
2008.1.25 Taiyuan University of Technology in China 30
2007.11.23 Koyokai, TUS 29
2007.11.9 Fire Department of Noda City 3
2007.11.7 Ibaraki prefectural Hokota First High School 39
2007.10.9 Gunma prefectural Maebashiminami Senior High School 13
2007.10.2 Person connected of consignment study 39
2007.9.26 Board of Education of Noda City 18
2007.8.10 Open Campus 95
2007.8.9 Open Campus 32
2007.6.29 PTA of Tochigi prefectural Kuroiso High School 29
2007.6.20 Riso Consultant Engineer Society 8
2007.5.15 Person connected of consignment study 36
2007.5.1 Fire Department of Noda City
2007.4.23 Society of students studying abroad, TUS 30
2007.3.6 Okayama Gakugeikan High School 41
2007.2.19~22 Asian Fire Testing Workshop 13
2006.10.26 Ibaraki prefectural Namiki High school 40
2006.10.8 Home Coming Day 100
2006.9.3 Open Campus 51
2006.8.7 Open Campus 123
2005.12.21 Fire Prevention Division, Fire Department of Kakogawa City
2005.11.17 Making DVD of 125th anniversary, TUS
2005.11.17 Ibaraki prefectural Midorioka High School 48
2005.10.19 Nigata prefectural Naoetsu High School 39
2005.9.27 Fukuoka prefectural Kurate High School 33
2005.7.26 Open Campus 60
2005.7.26 D group, Gunma prefectural Takasaki High School 21
2005.7.26 B group, Gunma prefectural Takasaki High School 22
2005.7.8 Gathering for discussions on private industrial colleges or institutes 31
2005.4.25 Society of students studying abroad, TUS 15
2005.3.19 Society of graduates, TUS 15
2005.3.8 Participants of 2nd international symposium 120

Center for Fire Science and Technology, Research Institute for Science and Technology, Tokyo University of Science
Address : Yamasaki 2641, Noda-shi, Chiba 278-8510, Japan
Telephone Number : +81-4-7124-1501 (Key Number)
Extension Number : 5036 (Research Support Services),
Fax number : +81-4-7123-9763
Access :5 minutes on foot from Unga station of the Tobu Noda Line
Google Map is the confirmed